LoRaWAN Analog Input Module: Wireless Data Acquisition for Industrial Sensors
Industrial facilities often have hundreds of sensors measuring pressure, liquid level, temperature and other process variables. Many of these instruments already use standard 4–20mA analog outputs.
However, collecting data from remote measurement points can be challenging. Installing communication cables across large facilities, pipelines, water treatment plants or agricultural sites can require significant infrastructure and maintenance work.
Replacing existing sensors with wireless models is not always necessary.
A LoRaWAN Analog Input Module provides another option. It collects signals from existing 4–20mA instruments, converts the analog measurements into digital data and transmits them through a LoRaWAN network.
The FANDE DR-LR2000 LoRaWAN Data Acquisition Module is designed for this purpose. It helps industrial users connect conventional analog sensors to modern wireless monitoring systems while retaining their existing measurement equipment.
1. What Is a LoRaWAN Analog Input Module?
A LoRaWAN analog input module is a device that collects analog signals from industrial sensors and sends the measurement data to a remote monitoring platform through LoRaWAN wireless communication.
Many industrial transmitters use a 4–20mA current loop because it provides a reliable way to transmit measurement signals over industrial wiring.
However, a traditional 4–20mA output does not provide wireless communication by itself.
A LoRaWAN analog input module bridges this gap.
Its basic functions include:
- Receiving analog signals from compatible industrial sensors.
- Converting current signals into digital measurement data.
- Transmitting the collected data through a LoRaWAN network.
- Connecting remote measurement points to gateways and monitoring platforms.
- Supporting remote monitoring without replacing the original sensor.
For example, an existing pressure transmitter can continue measuring pipeline pressure through its 4–20mA output. The DR-LR2000 collects that signal and sends the corresponding measurement data wirelessly.
The original sensor remains responsible for measurement, while the data acquisition module provides wireless connectivity.
2. How Does 4–20mA Signal Acquisition Work?
The 4–20mA current loop is widely used in industrial instrumentation.
The output current represents the measured process variable.
For a typical transmitter configured for a 0–100 bar range:
| Output Current | Corresponding Pressure |
|---|---|
| 4mA | 0 bar |
| 8mA | 25 bar |
| 12mA | 50 bar |
| 16mA | 75 bar |
| 20mA | 100 bar |
The relationship is linear when the transmitter is configured for a standard 4–20mA output.
The data acquisition module measures the incoming current and converts it into a digital value. The monitoring system can then interpret the signal using the sensor’s configured measurement range.
This means the DR-LR2000 does not need to measure pressure directly. It collects the electrical signal generated by the connected pressure transmitter.
The same principle applies to compatible level transmitters, temperature transmitters and other industrial instruments with 4–20mA outputs.
3. How the DR-LR2000 Connects Existing Sensors to LoRaWAN
![]()
The DR-LR2000 is an industrial wireless data acquisition module designed to convert standard 4–20mA analog signals into LoRaWAN data.
It provides a practical way to add wireless communication to existing measurement systems.
Its main functions include:
4–20mA Analog Input
The module accepts one standard 4–20mA analog input from a compatible industrial transmitter.
Digital Signal Conversion
The incoming current signal is sampled and converted into digital measurement data for wireless transmission.
12V Sensor Power Output
An integrated 12V output can supply compatible external sensors, helping simplify field installation.
LoRaWAN Wireless Communication
The module transmits measurement data through a LoRaWAN network rather than requiring a dedicated long-distance communication cable.
Remote Monitoring Integration
Collected data can be forwarded through a LoRaWAN gateway to a network server and monitoring platform.
This architecture allows users to retain existing industrial sensors while adding wireless data collection.
4. LoRaWAN Data Acquisition Architecture
A typical DR-LR2000 monitoring system consists of four main components.
Step 1: Industrial Sensor
An existing pressure, level or temperature transmitter generates a 4–20mA signal based on the measured process variable.
Step 2: DR-LR2000 Data Acquisition Module
The DR-LR2000 receives the analog signal, samples the measurement and prepares the data for wireless transmission.
Step 3: LoRaWAN Gateway and Network Server
The gateway receives the wireless packets and forwards them to the network server.
A compatible LoRaWAN network server, such as ChirpStack, can manage device communication and deliver the measurement data to other applications.
Step 4: Cloud Platform or Monitoring Application
The data can be displayed through dashboards, trend charts and alarm systems, depending on the selected software platform and integration.
Typical system architecture:
4–20mA Sensor → DR-LR2000 → LoRaWAN Gateway → Network Server → Cloud Platform / SCADA / Monitoring Application
This architecture is particularly useful when measurement points are distributed across large industrial sites or remote locations.
5. Why Use LoRaWAN Instead of Installing New Communication Cables?
Traditional wired monitoring systems provide reliable communication, but extending cables to remote locations can be expensive and time-consuming.
For some installations, cable routes require trenching, conduit, protective enclosures, additional labor and ongoing maintenance.
LoRaWAN offers an alternative for applications where low-power, long-range wireless communication is suitable.
Long-Range Communication
The DR-LR2000 supports transmission distances of up to 10 km under suitable line-of-sight conditions.
Actual communication range depends on terrain, buildings, metal structures, antenna installation, gateway location and local radio regulations.
Low-Power Operation
LoRaWAN Class A communication is designed for low-power devices.
The DR-LR2000 supports battery-powered configurations, including an ER34615 lithium battery option. A solar-assisted configuration is also available for suitable installations.
Battery life depends on reporting intervals, network conditions, battery selection and operating environment.
Flexible Network Deployment
LoRaWAN supports star-of-stars network architecture. Multiple remote devices can communicate with a gateway, reducing the need for individual long-distance communication cables.
Retaining Existing Sensors
Perhaps the most practical advantage is that users do not necessarily need to replace an existing 4–20mA transmitter when upgrading the communication system.
The original instrument continues measuring the process variable, while the DR-LR2000 adds wireless data acquisition.
6. High-Precision Analog Signal Acquisition
Wireless transmission is only useful when the original analog measurement is collected accurately.
The DR-LR2000 supports one 4–20mA analog input and provides the following signal acquisition specifications:
- Sampling accuracy: ≤0.01mA at room temperature.
- Resolution: 0.001mA.
- Compatible input: Standard 4–20mA.
- Sensor power output: Integrated 12V supply for compatible external sensors.
For a 4–20mA transmitter, small changes in current represent changes in the measured process variable.
Accurate signal acquisition helps preserve the information provided by the original sensor when transferring measurements to a wireless monitoring system.
The final system accuracy also depends on the connected sensor, its calibration, installation conditions and signal configuration.
7. LoRaWAN Compatibility and Wireless Configuration
The DR-LR2000 follows the LoRaWAN 1.0.3 Class A standard and supports OTAA (Over-The-Air Activation).
It is available in regional frequency configurations, including:
- EU868
- US915
- AS923
- AU915
- KR920
- IN865
The correct frequency version must be selected according to the deployment location and applicable radio regulations.
The module can be integrated with compatible LoRaWAN gateways and network servers.
For industrial projects, engineers should confirm the following before deployment:
- Regional frequency compatibility.
- Gateway and network server compatibility.
- Sensor current output and wiring configuration.
- Required reporting interval.
- Wireless coverage at the installation location.
- Battery or external power requirements.
These checks help ensure that the sensor, acquisition module and wireless network operate as a complete system.
8. Typical Applications of LoRaWAN Analog Input Modules
A LoRaWAN analog input module is particularly useful when industrial sites need to collect data from existing analog instruments at remote locations.
Remote Pressure Monitoring
Connect an existing 4–20mA pressure transmitter to monitor pipelines, pumps, compressors and hydraulic equipment.
Tank Level Monitoring
Collect signals from existing level transmitters to monitor storage tanks, water reservoirs and chemical tanks.
Temperature Monitoring
Connect compatible temperature transmitters to collect process or environmental temperature data remotely.
Water and Wastewater Systems
Monitor pressure, liquid level and other process parameters across distributed pumping stations and treatment facilities.
Agriculture and Irrigation
Collect analog measurements from remote monitoring points where conventional communication infrastructure is difficult to install.
Oil and Gas Facilities
Connect existing industrial instrumentation to wireless monitoring networks across pipelines and distributed equipment.
The suitability of each application depends on the sensor output, installation environment, wireless coverage and required reporting frequency.
9. DR-LR2000 LoRaWAN Data Acquisition Module: Key Specifications
| Parameter | Specification |
|---|---|
| Product | DR-LR2000 |
| Communication | LoRaWAN 1.0.3 Class A |
| Analog Input | 1 × 4–20mA |
| Sampling Accuracy | ≤0.01mA at room temperature |
| Resolution | 0.001mA |
| Receiver Sensitivity | Up to -138dBm |
| Transmission Range | Up to 10km LOS |
| Activation | OTAA |
| Sensor Power Output | 12V |
| Operating Temperature | -45°C to +85°C |
| Battery Options | ER34615 or 2 × 18650 with solar-assisted configuration |
| Regional Bands | EU868, US915, AS923, AU915, KR920, IN865 |
Actual wireless range and battery life depend on installation conditions, reporting intervals, antenna configuration and network settings.
For complete wiring information and ordering options, refer to the DR-LR2000 product documentation.
10. Upgrade Existing Industrial Sensors Without Replacing Them
Modernizing an industrial monitoring system does not always mean replacing every installed instrument.
If an existing pressure, level or temperature transmitter already provides a compatible 4–20mA output, it may be possible to retain the sensor and upgrade only the data communication method.
The DR-LR2000 provides a bridge between conventional analog instrumentation and LoRaWAN wireless networks.
By combining existing 4–20mA sensors, wireless data acquisition and a suitable monitoring platform, industrial users can extend monitoring coverage to remote locations without building a new wired communication network for every measurement point.
For facilities with distributed sensors, this approach can simplify system expansion and reduce the infrastructure required for remote data collection.
Conclusion
A LoRaWAN analog input module provides a practical way to connect traditional industrial sensors to modern wireless monitoring systems.
The FANDE DR-LR2000 supports 4–20mA analog signal acquisition, LoRaWAN 1.0.3 Class A communication, OTAA activation and an integrated 12V sensor power output.
It allows compatible existing pressure, level and temperature transmitters to become part of a remote wireless monitoring network without replacing their original measurement technology.
Looking to connect your existing 4–20mA sensors to a LoRaWAN network?
Contact FANDE with your sensor type, output signal, installation location and preferred reporting interval. Our engineering team can help you select the appropriate DR-LR2000 configuration.
Explore the DR-LR2000 LoRaWAN Data Acquisition Module
🔧 Need a Reliable DR-LR2000 LoRaWAN Data Acquisition Module?
Contact our engineering team for a free consultation on DR-LR2000 solutions tailored to your application.
Tags: #DR-LR2000