DR3601 Digital Pressure Controller

DR3601 Digital Pressure Controller

The 3601 series is an intelligent digital pressure switch with 2 or 5 relays, it integrates pressure measurement, LED display, 4-20mA output and relay control. And It is of full electronic structure. The front end of the pressure controller adopts oil pressure resistance pressure sensor with isolation film. It is converted by high-precision A/D, processed by microprocessor, the outputs can be one analog and two switching values. The pressure controller switch with relay is flexible to use, simple to operate, easy to debug, safe and reliable.

Applications

  • Petroleum, chemical, electric power
  • Mechanical engineering
  • Process control and automation
  • hydrology and flow pressure measure
  • Hydraulic pressure

Features

  • 4-digit LED display, real-time pressure measuring;
  • 2 relays or 5 relays output;
  • Support 4-20mA, RS485 output;
  • Power supply 24 VDC or 220 VAC
  • Preset switch point, hysteresis switching output;
  • Switch point at any pressure within the range;
  • The switch difference can be set arbitrarily;
  • Easy to operate, key setting parameters on site;

Technical Specs

Measurement range-1bar…0bar~0.1bar…1000barOutput2 relays/5 relays +4~20mA+RS485
Pressure typegauge, absolute or sealed gauge pressureContact LoadDC24V 3A/AC220V 3A
Over pressure200%FSAmbient temperature-20℃~70℃
Accuracy± 0.25% FS / ± 0.5% FSPressure interfaceNPT1/2 NPT1/4 G1/2 G1/4 M20 * 1.5
Stability±0.1%FS(1 year)Relative humidity≤80%
Housingstainless steel 304Protection levelIP65
Diaphragmstainless steel 316LPower supply24V DC/220V AC

Ordering Guide

DR3601Digital Pressure Switch
Range-1bar…0bar~0.1bar…1000bar
[0~X]barX: the actual measured pressure
CodeInstallation
Z1Radial mounting
Z2Axial installation
CodeRelay
R12 Relay
R25 Relay
O14-20mA
O2RS485
CodeInput Power
U124VDC
U2220VAC
CodeNotes
C1M20x1.5 male, face type seal
C2M20×1.5 male, waterline seal
C3G1/2 male
C4G1/4 male
C5G1/4 female
C6NPT1/2 male
C7NPT1/4 male
GGauge
AAbsolute
SSealed gauge
DR3601-[0~1]barZ1R1O1U1C4GThe whole spec.

Outline Construction (Unit: mm)

DR3601 Construction

2 Relay Plug Connection

Fandesensor DR3601 Pressure Switch 2-Relay Plug Description

5 Relay Plug Connection

Fandesensor DR3601 Pressure Switch 5-Relay Plug Description

FAQ

What is an electronic pressure switch?

Electronic pressure switches are based on electronic pressure sensors, which not only determine whether a setting switch point has been reached, but also transmit the actual measured pressure. it often feature a display from which pressure measurements can be read, as well as flexible settings and programming. Switching point, output signal, delay time, hysteresis and many other parameters can be individually adjusted to suit your application.

What’s the Max Load of the pressure controller?

Limited by contact capacity, AC220V 3A or DC24V 3A, If the capacity of the load is more than the restriction, a extra contactor is necessary.

How to Calibrate a Pressure Switch?

For pressure switches, Accurate calibration is a critical step in ensuring process quality and the safe operation of equipment. The setup is similar to pressure gauge calibration, except now a voltage or continuity across a set of switch contacts needs to be read either by a (Digital Multimeter) DMM or the calibrator.

Need Help with Easier Pressure Measurement Solutions? We Are Experts!