DR3513 Differential Pressure Switch

DR3513 Differential Pressure Switch

DR3513 Differential Pressure Switch

The differential pressure switch is designed for boiler steam, it has a SPDT switch to control the power supply ON/OFF by detecting the change of pressure. When the system pressure exceeds the set value, the microswitch acts and the blocking circuit plays a protective functions on the system. so It plays an important role in the boiler water tower pressure regulation system. The temperature range up to 180 ℃, and the contact load 120Vac/10A, 240Vac/5A, It can meet the needs of most scenarios. And service time up to 100000 times make it suit for long-term working.

Applications

  •  It is suitable for pressure control, pressure limit and alarm of non corrosive liquid, gas and steam.

Features

  • Medium temperature can reach 180 ℃;
  • Built in SPDT Switch, stable and reliable;
  • 120VAC 10A/240VAC 5A contact loads;
  • 100000 times long service life;

Technical Specs

Measurement range2-15 psi;
5-50 psi;
10-150 psi;
Power120Vac;
240Vac;
Differential pressure2-6 psi;
6-14 psi;
10-22 psi;
Rated contact load120Vac: 8.0 AFL, 48.0 ALR, 10.0 A resistive;
240Vac: 5.1 AFL, 30.6 ALR, 5.0 A resistive;
Mediumair, water, oilContact modeSPDT microswitch
Air tightnesskeep pressure at 85 psi for 1 minute without leakageContact resistance< 25mΩ
6. Medium temperature– 37 ℃ ~ 180 ℃, non icing stateElectrical life50000 times
Ambient temperature– 37 ℃ ~ 66 ℃Diaphragmstainless steel
Mechanical life100000 timesInterfaceNPT1/4-18

Ordering Guide

Outline Construction (Unit: mm)

FAQ

What is the principle of differential pressure switch?

Generally, it includes two diaphragm chambers, and each chamber contains two sealing diaphragms and a differential pressure diaphragm seal. The high pressure and low pressure enter the high pressure chamber and low pressure chamber respectively, and the differential pressure deforms the pressure-sensitive diaphragm, then through the mechanical structure such as the railing spring, the micro switch is finally activated to output the electrical signal.

What is a differential pressure switch used for?

These switches are used to sense pressure differences between two points in a system, and actuate power ON and OFF if a pre-defined difference is met.

What is differential pressure switch for HVAC?

HVAC systems use these switches to measure flow rates and pressures in lines and rooms. The switch help a system to efficiently and economically operate heating, ventilation, and air-conditioning systems. so, it is the core of controlling an HVAC system.

Need Help with Easier Pressure Measurement Solutions? We Are Experts!