DR3422 Differential Pressure Transducer


DR3422 Differential Pressure Transducer
The DR3422 is a micro differential pressure transducer, which adopts high-precision low pressure sensor to offer measuring range from -1bar up to 1bar, and output 4-20mA, 0-5 or RS485. Through high-performance MCU correct and compensate nonlinearity and temperature drift, the differential pressure sensor can realize accurate measurement of pressure signal. A LED display is optional to read the pressure on site. With a solid aluminum alloy housing, it is easy to install and operate.
Applications
- Air compressor, air conditioning, HVAC
- Wind tunnel pressure test
- Industrial process control
- Medical equipment
- Greenhouse pressure
Features
- Aluminum alloy shell sealing design, small size, good appearance
- Stable performance, good anti-interference performance
- The output current and voltage signals are optional
- Pagoda head Φ 6, Φ 8 pressure connection optional
Technical Specs
Measurement range | -1bar~0bar~1bar | Zero thermal drift | ≤±0.03%FS/℃ |
Media | Dry air | Span thermal drift | ≤±0.03%FS/℃ |
Over pressure | 200%FS | Compensated Temp. | 0℃ ~ +60℃ |
Accuracy | ±0.2% FS/±0.5% FS | Working temp. | -30℃ ~ +70℃ |
Stability | ±0.3%FS(1 year) | Storage Temp. | -30℃ ~ +70℃ |
Output | 4mA~20mA DC(2-wire); 0/1V~5/10V DC(3-wire); | Pressure interface | NPT1/2 NPT1/4 G1/2 G1/4 M20 * 1.5 |
Load | ≤(U-11)/0.02Ω(2-wire); ≥10k(3-wire); | Insulation resistance | 100MΩ@50V DC |
Housing | Aluminium alloy | Protection level | IP65 |
Diaphragm | stainless steel 304 | Power supply | 11V~28VDC; 12V~28VDC; |
Ordering Guide
DR3422 | Differential Pressure Transmitter | |||||
Range | -1bar~0bar~1bar | |||||
[0~X]bar | X: the actual measured pressure | |||||
Code | Output signal | |||||
E | 4mA~20mA DC | |||||
V1 | 1V~5V DC | |||||
V2 | 0V~5V DC | |||||
V3 | 0V~10V DC | |||||
R2 | RS485 | |||||
Code | Notes | |||||
B2 | Cable connection | |||||
Φ6 | Φ6 Pagoda head | |||||
Φ8 | Φ8 Pagoda head | |||||
L | LED Display(mA, RS485) | |||||
DR3422- | [0~1]bar | E | B2Φ6 | The whole spec |
Outline Construction (Unit: mm)

Electrical Connection

DR3422 Differential Pressure Transducer Applications


FAQ
What’s the wind pressure transmitter?
Describes a pressure transducer which was specially developed to measure wind pressures exerted in buildings. The instrument, which gives an electrical output, is suitable for measuring pressure in the range of -1bar-1bar. The frequency response enables pressure fluctuations lasting only 10ms to be recorded.
What is a differential pressure transducer used for?
A differential pressure transducer is an instrument that can consistently and accurately detect a pressure drop in a pipe and then use the pressure measurement on either side to provide the differental pressure within the pipe. It output a standrad signal required by pressure control system.
What’s is the smallest differential pressure?
The smallest differential pressure is 100Pa. Common ranges include the following, 0-100Pa, 0-200Pa, 0-300Pa, 0-1KPa, 0-2KPa, 0-3KPa, 0-4KPa, 0-5KPa, 0-10KPa, -100~100Pa, -200~200Pa, -1~1KPa, -3~0KPa, -5~0KPa. If the range is out of the list, please contact us for help.