Making PLC Integration Easier with a 4-20mA Pressure Transmitter

Making PLC Integration Easier with a 4-20mA Pressure Transmitter

Why Signal Compatibility Matters in Industrial Pressure Monitoring

Industrial automation systems rely on accurate measurement signals to monitor pressure and control equipment.

In many applications, pressure transmitters are connected directly to PLCs, DCS systems or other industrial controllers. However, not every transmitter provides an output signal that matches the control system’s input requirements.

When the signal types are incompatible, additional signal converters or interface modules may be required. This can increase wiring complexity, commissioning time and maintenance requirements.

A 4-20mA pressure transmitter for PLC integration offers a straightforward solution for many industrial applications.

The 4–20 mA current loop is widely used in industrial instrumentation because it supports long-distance signal transmission and provides a practical interface for compatible analog input modules.

The FANDE DR3401 General Purpose Pressure Transmitter provides a standard two-wire 4–20 mA output for industrial pressure monitoring and control applications.

1. Why 4–20mA Is Widely Used in Industrial Automation

The 4–20 mA current loop is a common analog signal standard in industrial process measurement.

Unlike voltage signals, current-loop transmission is generally less affected by voltage drops along the cable, provided the transmitter and receiving circuit operate within their specified load and power limits.

Several characteristics make it suitable for industrial applications.

Compatibility with PLC Analog Inputs

Many PLC systems include analog input modules designed to receive 4–20 mA signals.

A compatible pressure transmitter can therefore connect directly to the PLC input without requiring a separate signal conversion stage.

Long-Distance Signal Transmission

Current-loop signals are widely used for transmitting process measurements between field instruments and control cabinets.

Proper cable selection, grounding and loop design remain important for reliable operation.

Live Zero

The 4 mA lower limit is known as a live zero.

It allows the receiving system to distinguish a valid zero-scale measurement from certain wiring or power-loss conditions, depending on the PLC configuration and fault-detection strategy.

Standardized Process Measurement

Using a common signal interface simplifies instrument selection and helps maintain consistency across different measurement points in an automation system.

2. Understanding a Two-Wire 4–20mA Pressure Transmitter

A two-wire pressure transmitter uses the same pair of wires for power supply and signal transmission.

The transmitter converts measured pressure into a proportional current signal.

For example, when a transmitter is configured for a 0–100 bar range:

PressureOutput Signal
0 bar4 mA
25 bar8 mA
50 bar12 mA
75 bar16 mA
100 bar20 mA

The PLC analog input reads the current and converts it into a corresponding engineering value.

The exact scaling parameters must be configured according to the transmitter’s measuring range and the PLC input module.

3. DR3401: A General Purpose Pressure Transmitter with 4–20mA Output

The FANDE DR3401 General Purpose Pressure Transmitter is designed for industrial pressure measurement applications.

It uses a piezoresistive pressure sensor and a dedicated signal processing circuit. The transmitter supports zero-point and full-scale output adjustment.

Its two-wire 4–20 mA output provides a standard interface for compatible PLC and industrial monitoring systems.

Key Features

  • Standard 4–20 mA output: Two-wire current-loop signal for compatible industrial control systems.
  • Wide measurement range: Configurable pressure ranges from -1 bar to 1000 bar.
  • Accuracy options: ±0.25% FS and ±0.5% FS.
  • Pressure types: Gauge, absolute and sealed gauge pressure.
  • Industrial construction: Stainless steel 304 housing and stainless steel 316L diaphragm.
  • Protection rating: IP65.
  • Reverse polarity protection: Helps protect the instrument against incorrect power connection.
  • Lightning protection: Three-level lightning protection design.

These features make the DR3401 suitable for general industrial pressure monitoring, hydraulic systems, process control and automation applications.

4. Connecting DR3401 to a PLC System

A typical two-wire 4–20 mA pressure measurement arrangement includes a pressure transmitter, DC power supply and PLC analog input.

The basic signal path is:

Process Pressure → DR3401 → 4–20mA Signal → PLC Analog Input → Monitoring System

Before installation, engineers should verify the following:

  1. Power supply: The DR3401 requires a compatible 11–28 VDC supply.
  2. Analog input type: Confirm that the PLC module supports a two-wire 4–20 mA input.
  3. Input scaling: Configure the PLC to match the transmitter’s pressure range.
  4. Loop resistance: Ensure the total loop load remains within the transmitter’s permitted load.
  5. Wiring polarity: Follow the transmitter and PLC wiring diagrams.
  6. Grounding and shielding: Apply suitable installation practices to reduce electrical interference.

Once connected and configured, the PLC can receive pressure measurements for display, data recording, alarm processing and process control.

5. Selecting the Correct Pressure Range for Your Application

Choosing the correct pressure range is essential for effective measurement.

For example, if a process normally operates around 50 bar, a 0–100 bar transmitter may be appropriate, depending on the maximum expected pressure and required measurement accuracy.

A range that is unnecessarily large may reduce the usefulness of the measurement resolution in the control system.

When selecting a DR3401 configuration, consider:

  • Normal operating pressure
  • Maximum expected pressure
  • Required measurement accuracy
  • Pressure type: gauge, absolute or sealed gauge
  • Process connection
  • Electrical output
  • Operating temperature

The DR3401 supports a wide range of pressure connections, including NPT1/2, NPT1/4, G1/2, G1/4 and M20×1.5, depending on the selected configuration.

6. Important Considerations for High-Temperature Extrusion Applications

Plastic extrusion involves high process temperatures, and the pressure measurement assembly must be suitable for the actual installation conditions.

A general-purpose pressure transmitter should not automatically be treated as a direct-contact melt pressure sensor.

The DR3401 product specification lists a compensated temperature range of 0°C to +50°C and a working temperature range of -30°C to +70°C.

These specifications do not establish suitability for direct measurement of molten polymer at 400°C or above.

For direct melt pressure measurement, engineers should select a dedicated high-temperature melt pressure transducer with an appropriate diaphragm, thermal protection and process connection.

The DR3401 may be considered for other pressure measurement points in an extrusion production system when the pressure medium and installation temperatures are within its specified limits.

7. DR3401 Technical Specifications

ParameterSpecification
Measurement range-1 bar to 1000 bar
Pressure typeGauge, absolute or sealed gauge
Accuracy±0.25% FS / ±0.5% FS
Long-term stability±0.30% FS (1 year)
Output4–20 mA DC, two-wire
Alternative output0/1–5/10 V DC, three-wire
Power supply11–28 VDC
Compensated temperature0°C to +50°C
Working temperature-30°C to +70°C
HousingStainless steel 304
DiaphragmStainless steel 316L
Protection ratingIP65
Pressure connectionsNPT1/2, NPT1/4, G1/2, G1/4, M20×1.5

Specifications depend on the selected configuration. Please confirm the required pressure range, output and connection before ordering.

8. Applications of 4–20mA Pressure Transmitters

The DR3401 can be considered for general industrial pressure measurement applications where a standard analog signal is required.

Typical applications include:

Hydraulic Systems

Monitor hydraulic pressure in power units, pipelines and industrial machinery.

Process Control

Transmit pressure readings to PLC or DCS systems for process monitoring and control.

Water and Pump Systems

Monitor pipeline pressure and provide measurement signals to compatible automation equipment.

Mechanical Engineering

Integrate pressure measurement into industrial machines and production equipment.

Industrial Automation

Provide a standard analog pressure signal for data acquisition, monitoring and alarm functions.

Conclusion: Simplify Industrial Pressure Measurement with Standard 4–20mA Output

Choosing a pressure transmitter with a compatible output signal can simplify industrial automation projects.

The 4–20 mA current loop provides a widely used interface for PLC-based pressure monitoring, helping engineers reduce unnecessary signal conversion and simplify system integration.

The FANDE DR3401 General Purpose Pressure Transmitter offers configurable pressure ranges, two-wire 4–20 mA output, multiple pressure connection options and industrial stainless steel construction.

For applications requiring standard analog pressure measurement, the DR3401 provides a practical option for integration with compatible PLC and process control systems.

Looking for a 4–20mA pressure transmitter for your PLC system?

Explore the FANDE DR3401 General Purpose Pressure Transmitter or contact our team with your pressure range, power supply and connection requirements.